DXE GAS HEATER

DESCRIPTION

DXE

DXE is a unique heating concept for poultry houses as it combines the benefits of a closed combustion circuit with the advantage of having the heater installed outside the house.

Indirect Fire

DXE is an indirect-fired heater (80 kW) with a closed combustion system. This means flue gases remain outside the house, eliminating the need to extract CO2 and water vapor from within. Ventilation volumes are significantly reduced, eliminating the need to heat large volumes of cold outside air, resulting in reduced gas consumption: energy savings of up to 25% are possible.

Humidity levels are significantly reduced compared to a direct heat source. This reduces the incidence of moisture-related diseases, such as Podo, due to drier litter. Bird morbidity and mortality are reduced, and yield per harvest is increased.

Biosecurity

The DXE heater is easily accessible for maintenance during the harvest cycle, as it is mounted outside the shed. This reduces the risk of infection, making biosecurity even more important for the breeder. Removing or lifting the heaters for cleaning is not required, as the heaters are mounted on the side wall of the shed.

Reliable Quality

The DXE was designed with the harsh conditions found in poultry houses in mind, requiring easy maintenance. The housing is made of steel with a special coating that seals the insulation, reducing heat loss. The burner technology is based on the proven Winterwarm heaters. The risk of burner head contamination is extremely low, as the combustion process uses clean outside air. The heater is easily accessible from the front. The heat exchanger and fan are accessible through a large hatch for cleaning between crops.

Characteristics:

  • Indirect gas heater;
  • Located outside the house;
  • High air flow;
  • 100% return air circulation;
  • Closed combustion circuit = no flue gases in the house;
  • No CO2 in the house = less ventilation = less energy consumption = lower costs;
  • Improved biosecurity;
  • Favorable growing conditions;
  • Power: 80 kW;
  • Reliable tubular heat exchanger;
  • Reliable, proven technology;
  • CE approved;
  • Easy to clean and maintain.

 

 

Description Unit of measurement DXC 60 DXC 80 DXC 100
Nominal thermal load kW 65,5 83 108
Nominal thermal power kW 60 76 99
Efficiency maximum power % 0,915 0,915 0,915
Air outlet m3 / h 6000 8000 10000
Stream length m. 40 45 45
Electrical power W 800 900 1400
Power consumption А 3,5 3,9 6,1
Pure frequency Hz 50 50 50
Sound level dBa 68 68 68
Weight kg 140 150 175
Max. gas consumption G25 m3 / h 7,8 9,9 12,8
Max. gas consumption G20 m3 / h 6,9 8,8 11,4
Max. gas consumption G31 m3 / h 5,2 6,6 8,6
Gas connection G" 3/4 3/4 3/4
Chimney diameter mm 130 130 130

 

 



For more information, please visit the manufacturer's website at www.winterwarm.com or contact our specialists.